"2 core cable 2 x 10mm2"
Please try a different search term or browse our product categories.
白銅ビルワイヤー PVC絶縁単心家庭用電線
BV 2.5mm2 White PVC Insulated Single Core Copper Building Wire 450/750V Household Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain ...
1500V 太陽光電池ケーブル ハロゲンフリー 5級 柔軟な太陽光電池線
H1Z2Z2-K 6.0mm² TUV 1500V DC Solar Main Cable UV Resistant PV Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) ...
DCソーラーワイヤ 6.0mm2 PV1-F TUV UV耐性光伏ケーブル PVストリング メインケーブル
DC Solar Wire 6.0mm² PV1-F TUV UV Resistant Photovoltaic Cable PV String Main Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper ...
3x300mm2 中圧電力ケーブル Al XLPE スーパーヘビーアルミニウムケーブル
Super Heavy Aluminum Cable YJLV22 3x300mm² 8.7/10kV 8.7/15kV Armored XLPE MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7...
高容量MV装甲ケーブル 150mm2 XLPE 3芯アルミニウムケーブル
High Capacity Aluminum Cable 3 Core 150mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
ジャイアントMVケーブルYJV22 3x400mm² 8.7/15kV アーマードXLPEパワーケーブル
Giant MV Cable YJV22 3x400mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; Uₘ = ...
超重型MVケーブル YJV22 3x185mm2 8.7/15kV 装甲型XLPE電源ケーブル
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
3コア armored MVケーブル YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPEパワーケーブル
3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...