"2 core flexible cable 4x10mm2"
Please try a different search term or browse our product categories.
Gelb PVC Kupfer Single Core Switch Wire 450 V 750 V Lichtsteuerung Kabel
Yellow BV 2.5mm² PVC Copper Single Core Switch Wire 450/750V Lighting Control Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...
PV-Kabel PV1-F 4,0mm² TUV UV-beständig wetterfest 1500V DC Photovoltaik
PV Cable PV1-F 4.0mm² TUV UV Resistant Weatherproof 1500V DC Photovoltaic Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
Solarpanel-Verbindungskabel PV1-F 4,0mm² TUV 1500V DC wetterfestes PV-Kabel
Solar Panel Connection Cable PV1-F 4.0mm² TUV 1500V DC Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor...
8.7KV 10kV Mv Stromkabel Panzerwolkenkratzer Haupt Aluminiumkabel
Skyscraper Main Aluminum Cable YJLV22 3x400mm2 8.7/10kV 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...
T
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
S
Heavy Gauge MV Cable YJV22 3x150mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
4+1 Kern-Brandwiderstandskabel 120mm2+1x95mm2 BTTRZ Brand-Umspannkabel
Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...
Große feuerfähige Drähte 4x95mm2+1x70mm2 Mineralisoliertes Heizkabel
Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...