"1 electrical building wires"
Please try a different search term or browse our product categories.
1.0mm2 Massiv Kupferleiter 18 Awg Kautschuk Kupferdraht
BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards Compliance GB/T 5023.3-2008, JB/T 8734.2-2016 Certification CCC ...
Solar Hauptkabel PV1-F 6,0mm² TUV 1500V DC Heavy Duty PV Photovoltaik-Leitung
Solar Main Cable PV1-F 6.0mm² TUV 1500V DC Heavy Duty PV Photovoltaic Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
Gleichstrom-Solardraht 6,0 mm2 PV1-F TUV UV-resistentes Photovoltaikkabel PV-String Hauptkabel
DC Solar Wire 6.0mm² PV1-F TUV UV Resistant Photovoltaic Cable PV String Main Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper ...
Gleichstrom (PV) Solarkabel H1Z2Z2-K 4,0 mm2 Einzelkern aus Kupfer XLPE/XLPO isoliert
DC (PV) Solar Cable H1Z2Z2-K 4.0 mm² Single Core Tinned Copper XLPE/XLPO Insulated H1Z2Z2-K 1×4.0 mm² Photovoltaic (PV) DC Solar Cable. H = Harmonised EU designation · 1Z2Z2 = halogen-free (HFFR) insulation + halogen-free (HFFR) sheath, both cross-linked · K = flexible Class 5 conductor · 1×4...
S
Super Heavy MV Cable YJV22 3x300mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
BTTRZ X50mm2+1x25mm2 Feuerbeständiges Kabel Mineral Notstrom Kupferummanteltes Kabel
BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...
4x185mm2 + 1x150mm2 feuerfestes Kabel 0,6KV 1KV mineralisch isoliertes Kupferkabel
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
Große feuerfähige Drähte 4x95mm2+1x70mm2 Mineralisoliertes Heizkabel
Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...