"copper 4 cores cable"
Please try a different search term or browse our product categories.
4.0mm2 câble photovoltaïque TUV câble photovoltaïque non corrosif de 1500V
H1Z2Z2-K 4.0mm² TUV Certified Solar Cable 1500V DC Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...
Câble solaire photovoltaïque monoconducteur 6.0mm2 TUV Xlpe Cu
1500V DC Solar Wire PV1-F 6.0mm² TUV XLPE Copper Photovoltaic Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, halogen...
Câble photovoltaïque DC Solar Wire PV1-F 4.0mm² TUV 1500V Cuivre XLPE
DC Solar Wire PV1-F 4.0mm² TUV 1500V Copper XLPE Photovoltaic Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
Câble moyenne tension 3x400mm2 blindé XLPE fil XLPE 26KV 35kV
YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC ...
Super lourd câble MV YJV22 3x300mm2 8.7/15kV câble d'alimentation XLPE blindé
Super Heavy MV Cable YJV22 3x300mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
Cable électrique ultra lourd YJV22 3x185mm2 8.7/15kV câble électrique XLPE blindé
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
BTLY câble à incendie 4x35 mm2 + 1x16 mm2 câble en aluminium pour les urgences
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...
4x185mm2 + 1x150mm2 câble ignifuge 0.6KV 1KV câble minéral isolé en cuivre
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...