4.0mm2 твердый медный проводник 450V 750V одноцепочечный медный провод
BV 4.0mm² Solid Copper PVC Insulated Building Wire 450/750V Easy Pull Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 4.0 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...
2.5мм2 одножильный медный проводник заземления твердый THHN огнестойкий
Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or stranded)...
H1Z2Z2-K 4,0 мм2 фотоэлектрический солнечный кабель TUV 1500V XLPE медный кабель
H1Z2Z2-K 4.0mm² TUV 1500V DC Solar Cable UV Resistant Halogen Free XLPE Copper Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z ...
IEC 62930 Солнечная проволока Консервированная медь 0,095 кг/м ПВ проволока для солнечных панелей
PV Cable PV1-F 6.0mm² TUV 1500V DC Low Smoke Halogen Free Solar Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, ...
?
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Высоковольтный кабель YJV22 3x95мм² 8.7/15кВ бронированный силовой кабель из сшитого полиэтилена
High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Основной распределительный кабель 3 жилы 70мм² YJV22 8.7/10кВ бронированный СПЭ
Primary Distribution Cable 3 Core 70mm² YJV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; ...
4+1-жильный огнестойкий кабель 120мм2+1x95мм2 BTTRZ огнестойкий кабель для подстанций
Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...