único cabo do núcleo
Cable de núcleo único ZR-YJV 1 X 300mm2 Retardante de chama 0,6/1kV Isolamento XLPE de cobre sólido
ZR-YJV 1*300mm² Flame Retardant Single Core Cable, 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×300 mm² Single core, 300 ...
1*150mm2 Fios de cobre de núcleo único XLPE Isolamento PVC para fiação de construção
ZR-YJV 1*150mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Construction Wiring Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×150 mm² Single core, 150 mm² copper ...
1x120mm2 cabo de núcleo único de calibre completo cobre puro antienvelhecimento resistente à chama potência
ZR-YJV 1*120mm² Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Powe Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×120 mm² Single core, 120 mm² copper conductor Construction ...
Cabo Unipolar Blindado Classe 2 1*95mm2 com Revestimento de PVC para Energia Predial
ZR-YJV 1*95mm² Single Core Cable, 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Building Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×95 mm² Single core, 95 mm² copper conductor ...
1 x 70 mm2 cabo de núcleo único cobre sólido XLPE isolante PVC casaco para energia de construção
ZR-YJV 1*70mm² Single Conductor , 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Building Power Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×70 mm² Single core, 70 mm² copper conductor ...
Cabo Terra Unipolar de Poliolefina ZR-YJV 1 X 35mm2 Condutor Único 0.6/1kV Potência Interior
Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed ZR-YJV 1×35 is a flame-retardant, copper-conductor, XLPE-insulated, PVC-sheathed power cable for 0.6/1 kV distribution, designed and tested ...
1x25mm2 cabo de núcleo único cobre puro XLPE isolamento para cablagem de energia interna
ZR-YJV 1*25mm² Flame Retardant Single Core Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Indoor Power Wiring Code Mean:ZR-Flame Retardant, YJ-XLPE Insulation, V-PVC Outrt Sheathed. ZR-YJV 1×25 mm² — Detailed Product Introduction Cable Designation & Meaning Code Meaning ZC Flame retardant ...
1x16mm2 cabo elétrico de núcleo único oxigénio livre auto-extinguir 1 núcleo 16mm cabo
1x16mm² Single Core Electrical Cable Oxygen Free Self Extinguishing 1 Core 16mm Cable Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×16 mm² Single core, 16 mm² copper conductor Construction : ...
1x185mm2 Cable de núcleo único Conductor de cobre enrolado Pvc Envelope resistente ao fogo Nível C
0.6/1kV ZC-YJV 1x185mm² Stranded Copper Conductor XLPE Insulation PVC Outer Sheath Fire Resistant C Level Technical Datasheet — ZC-YJV 0.6/1 kV 1×185 mm² 1. Cable Designation & Meaning Code Meaning ZC Flame retardant, Class C (bundled combustion test) YJ XLPE (cross-linked polyethylene) ...