"hv cable 26kv"
Please try a different search term or browse our product categories.
कंड्यूट इंस्टॉलेशन के लिए ब्लैक बीवी 2.5 मिमी2 सॉलिड कॉपर कोर सीयू पीवीसी वायर
Black BV 2.5mm² Solid Copper Conductor PVC Wire for Conduit Installation Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or ...
सफेद तांबा बिल्डिंग वायर पीवीसी अछूता एकल कोर घरेलू विद्युत केबल
BV 2.5mm2 White PVC Insulated Single Core Copper Building Wire 450/750V Household Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain ...
यूवी प्रतिरोधी सौर पैनल पीवी केबल PV1-F XLPO सौर सरणी केबल
Solar Array Cable PV1-F 6.0mm² TUV 1500V DC UV Resistant PV String Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, ...
3x400mm2 मध्यम वोल्टेज केबल XLPE बख्तरबंद XLPE तार 26KV 35kV
YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC ...
3x400mm2 मध्यम वोल्टेज पावर केबल एल्यूमीनियम XLPE आर्मर्ड MV केबल 8.7kV
YJLV22 3x400mm² Aluminum XLPE Armored MV Cable 8.7/15kV Cost Effective Underground Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×400 mm² Three cores, each ...
3x120mm2 मध्यम वोल्टेज पावर केबल 8.7kV 15kV एल्यूमीनियम एमसी केबल
Industrial Main Aluminum Cable YJLV22 3x120mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated ...
एल्यूमीनियम कॉन्सेंट्रिक न्यूट्रल एमवी केबल 3x95mm2 3 कोर एल्यूमीनियम आर्मर्ड केबल
Main Distribution Aluminum Cable YJLV22 3x95mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
BTTRZ लौ retardant केबल 4x150mm2 + 1x120mm2 खनिज अछूता केबल
Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...